Murphy PV101-C-HAZ ATEX防爆显示器
PowerView. PV101-A-HAZ
& PV101-C-HAZ
ATEX Certified, Zone 2, Category 3G
II 3G IIC T3 Ta = -10°C
to 70°C (14°F to 158°F)
Environmental Sealing: IP68, ±5 PSI (±34.4 kPa)
PowerView PV101-A-HAZ & PV101-C-HAZ
The PowerView PV101 display is a multifunction tool that enables equipment operators to view standard engine and transmission parameters as well as active
and stored trouble codes. The device can show a single parameter or display four parameters simultaneously.Diagnostic capabilities include codes with text
description for most common fault conditions. The enhanced alarm indicators have ultra-bright alarm and shut-down LEDs (amber and red). The HAZ models
of the PV101-C and PV101-A have many features including:
? ATEX Certified, Zone 2, Category 3G II 3G IIC T3 Ta = -10°C to 70°C (14°F to 158°F)
? Tier 4 Emissions Implementation (PV101-C only) – Three icons indicating Active Regeneration, Inhibit Regeneration and Diesel Particulate Filter (DPF) Restricted. Menu offers Auto DPF Regen and Request DPF Regen.
? OEM Menu – A password protected menu offers access to MODBUS Setup, Engine Speed Control ON/OFF and other critical menu items that require restricted access.
? TSC1 (Torque Speed Control) (PV101-C only) – Allows user to set run speed via CAN if supported by engine manufacturer.
? Additional 4-Up Screen (PV101-C only) – Allows user to have two 4-Up screens to toggle between. Second user configurable screen is defaulted to show Tier 4 parameters: DEF Level (DieselExhaust Fluid Level), DPF Active Regen Status, Exhaust Filter Outlet Temp and Exhaust Filter Inlet Temp.
? Multiple language options ? Russian, Czech, Brazilian Portuguese, Chinese and Japanese models have been added to the line of existing languages (English, Spanish, French, German and Italian).
? Sender Input ? Select between backlight dimmer function or fuel level. Can be calibrated to use non-Murphy fuel senders.
? Service Reminders – Five service reminders allow users to set hours for: Change Engine Oil, Change Air Filters, Change Hydraulic Oil, Service Engine and Service Machine.
? Select Source Address – Select which address the PV101 will claim on the bus.
? Select CAN bus Data Rate – Allows user to select CAN bus data rate.
? PV101-C Configuration Tool (PV101-C only) – PC tool allows users to create, view, edit and download configurations for the PV101.
? The PV101-C Display Gauges – Compatible with PVA and PVM gauges, as well as additional J1939 I/O modules.
PowerView PV101-A-HAZ & PV101-C-HAZ PDF Catalog
The PowerView PV101 display is a multifunction tool that enables equipment operators to view standard engine and transmission parameters as well as active and stored trouble codes. The device can show a single parameter or display four parameters simultaneously. Diagnostic capabilities include codes with text description for most common fault conditions. The enhanced alarm indicators have ultra-bright alarm and shut-down LEDs (amber and red).
The HAZ models of the PV101-C and PV101-A have many features including:
. ATEX Certified, Zone 2, Category 3G
II 3G IIC T3 Ta = -10°C
to 70°C (14°F to 158°F)
.Tier 4 Emissions Implementation (PV101-C only) – Three icons indicating Active Regeneration, Inhibit Regeneration and Diesel Particulate Filter (DPF) Restricted. Menu offers Auto DPF Regen and Request DPF Regen.
.OEM Menu – A password protected menu offers access to MODBUS Setup, Engine Speed Control ON/OFF and other critical menu items that require restricted access.
.
TSC1 (Torque Speed Control) (PV101-C only) – Allows user to set run speed via CAN if supported by engine manufacturer.
.Additional 4-Up Screen (PV101-C only) – Allows user to have two 4-Up screens to toggle between. Second user configurable screen is defaulted to show Tier 4 parameters: DEF Level (Diesel Exhaust Fluid Level), DPF Active Regen Status, Exhaust Filter Outlet Temp and Exhaust Filter Inlet Temp.
.Multiple language options . Russian, Czech, Brazilian Portuguese, Chinese and Japanese models have been added to the line of existing languages (English, Spanish, French, German and Italian).
.Sender Input . Select between backlight dimmer function or fuel level. Can be calibrated to use non-Murphy fuel senders.
.Service Reminders – Five service reminders allow users to set hours for: Change Engine Oil, Change Air Filters, Change Hydraulic Oil, Service Engine and Service Machine.
.Select Source Address – Select which address the PV101 will claim on the bus.
.Select CAN bus Data Rate – Allows user to select CAN bus data rate.
.
PV101-C Configuration Tool (PV101-C only) – PC tool allows users to create, view, edit and download configurations for the PV101.
.
The PV101-C Display Gauges – Compatible with PVA and PVM gauges, as well as additional J1939 I/O modules. The MurphyLink system includes the microprocessor-based PowerView Analog (PVA) Gages for displaying critical engine data broadcast by an electronic engine or transmission’s Engine Control Unit (ECU). Other components include engine RPM, oil pressure, coolant temperature and system voltage. A combination audible alarm/relay unit offers warning and shut-down alerts. Up to 32 components may be linked to the PowerView using a simple daisy chain wire connection scheme using RS485. The PowerView and all connected
components can be powered by either 12- or 24-volt systems.
Product Dimensions
In order to consistently bring you the highest quality, full-featured products, we reserve the right to change our specifications and designs at any time. MURPHY products and the Murphy logo are registered and/or common law trademarks of Enovation Controls, LLC. This document, including textual matter and illustrations, is copyright protected by Enovation Controls, LLC, with all rights reserved. (c) 2015 Enovation Controls, LLC. A copy of the warranty may be viewed or printed by going to http://fwmurphy.com/warranty.
Murphy PV101-C-HAZ仪表 Specifications
规格参数:
Operating Voltage
12/24V (8-32 VDC minimum and maximum voltage)
Reversed Polarity
Withstands reversed battery terminal polarity indefinitely within operating temperatures.
Environmental
ATEX Operating Temperature: -10°C to 70°C (+14°F to 158°F)
Storage Temperature: -40°C to 85°C (-40°F to 185°F)
Environmental Sealing: IP68, ±5 PSI (±34.4 kPa)
Power Supply Operating Current
(@ 14VDC) 52 mA min: 300mA max
(@ 32VDC) 1A max (with LCD heater) CAN bus: SAE J1939 compliant Case: Polycarbonate / polyester
How To Order如何订货:
Maximum Panel Thickness: 3/8 inch (9.6mm)
Resistive Input: (user selectable as one of the following) Backlighting Potentiometer: 1K Ohm, 1/4 W Murphy Fuel Sender: 33 Ohn full, 240 Ohm empty set from the factory or programmable to work with non-Murphy fuel senders.
Fuel Sender Input: 33 Ohm full, 240 Ohm empty set standard from factory for use with Murphy Fuel Sender. Programmable for use with non-Murphy fuel senders.
Shipping Weights (all models): 1 lb. (450g) Shipping Dimensions (all models):
5 x 6 x 6 in. (127 x 152 x 152 mm) Clamp: PBT Connectors: 6-pin Deutsch DT Series
Part Number Model and Description Notes
型号订货
78700248; PV101-A-HAZ: Murphy Standard, Hazardous Environment English, Spanish, French, Italian German
78700581; PV101-C-HAZ: Murphy Standard, Hazardous Environment English, Spanish, French, Italian German
78700428 ; PV101 Shield: Impact Shield Assembly
78700430; HAZ Environment Kit: PV101-A-HAZ w/PV101 Shield English, Spanish, French, Italian German
如何订购
零件号 |
产品型号 |
产品描述 |
可选语言 |
78700244 |
PV101-A |
标准版 |
英文、法文、德文、西班牙文、意大利文 |
78700396 |
PV101-A-M01 |
俄文版 |
英文、法文、德文、西班牙文、俄文 |
78700409 |
PV101-A-M02 |
中文版 |
中文、英文 |
78700411 |
PV101-A-M03 |
日文版 |
日文、英文 |
Part Number Model Description Languages Available
Part Number |
Model |
Description |
Languages Available |
78700615 |
PV101-C-MSTD-TlER4 |
Murphy STD |
English, Spanish, French, Italian, German |
78700610 |
PV101-C-M01-TlER4 |
Murphy STD Russian |
English, Russian |
78700611 |
PV101-C-M02-TlER4 |
Murphy STD Chinese |
English, Chinese |
78700612 |
PV101-C-M03-TlER4 |
Murphy STD Japanese |
English, Japanese |
78700613 |
PV101-C-M04-TlER4 |
Murphy STD Brazilian Portuguese |
English, Brazilian Portuguese, French, German, Spanish |
78700614 |
PV101-C-M05-TlER4 |
Murphy STD Czech |
English, Czech, French, German, Spanish |
78700439 |
PV101-C |
Murphy STD |
English, Spanish, French, Italian, German |
78700497 |
PV101-C-M01-TlER4 |
Murphy STD Russian |
English, Russian |
78700498 |
PV101-C-M02 |
Murphy STD Chinese |
English, Chinese |
78700499 |
PV101-C-M03 |
Murphy STD Japanese |
English, Japanese |
78700500 |
PV101-C-M04 |
Murphy STD Brazilian Portuguese |
English, Brazilian Portuguese, French, German, Spanish |
78700501 |
PV101-C-M05 |
Murphy STD Czech |
English, Czech, French, German, Spanish |
78700435 |
PV101-C Configuration Tool Kit |
User Configuration Tool |
|
78700244 |
PV101-A |
Murphy STD |
English, Spanish, French, Italian, German |
78700396 |
PV101-A-M01 |
Murphy STD Russian |
English, Russian |
78700409 |
PV101-A-M02 |
Murphy STD Chinese* |
English, Chinese |
78700411 |
PV101-A-M03 |
Murphy STD Japanese* |
English, Japanese |
78700248 |
PV101-A-HAZ |
Murphy STD, Hazardous Environment |
English, Spanish, French, Italian, German |
78700581 |
PV101-C-HAZ |
Murphy STD, Hazardous Environment |
English, Spanish, French, Italian, German |
78700428 |
PV101 Shield |
Impact Shield Assembly |
|
78700430 |
HAZ Environment Kit |
PV101-A-HAZ with PV101 shield |
English, Spanish, French, Italian, German |
|
|
|
*Added features not available in these language models. |
- 产品资料下载
PV101-C
PV101-A
PV101-HAZ
Sales Bulletin - Model PV101-A-HAZ/PV101-C-HAZ (1411568; revision date - 09/2015)
|