XM500 module
XM500模块是一个可配置的输入/输出(I/O)模块,设计用于将模拟和数字输入和输出带到SAE J1939 CAN上。The XM500 module is a configurable Input/Output (I/O) module designed to bring analog and digital inputs and output onto the SAE J1939 CAN.
XM500非常适合将所需的附加信息带到J1939 CAN总线上,并且可以配置为广播故障代码并根据输入条件(如燃油油位低、液压油温度高等)激活数字输出。由于XM500使用J1939标准协议广播信息,信息可以是使用标准J1939显示模块(如PowerView 101)显示。The XM500 is ideally suited to bring the additional information needed onto the J1939 CAN bus and can be configured to broadcast fault codes and activate digital outputs per input condition such as fuel level low, hydraulic oil temperature high, etc. Because the XM500 broadcasts information using the J1939 standard protocol, the information can be displayed using standard J1939 display modules, such as the PowerView 101.
XM500 输入 / 输出模块可以把模拟量输入和开关量输入 / 输出并入 J1939 CAN 总线内。你也许需要监控很多发动机或传动系统 ECU 无法提供的信息,比如:油位、液压系统油压、或是发动机冷却液低位开关等信号, XM500 可以帮助你把这些信息转为 J1939 信号,并根据每一个输入条件,如低油位、高液压油温等进行配置并播送故障代码。 XM500 以 J1939 标准协议进行广播,因此可与符合 J1939 协议的显示器配合使用,比如 PV101 、 PV750 等 。
|
● CAN 总线 ( J1939 ) 专用的输入 / 输出模块
● 可与标准 CAN 总线 显示器配合使用
● 工作温度范围广
● 使用标准的德尔驰接口
● 可选定制服务 |
产品规格
工作电压: 8 ~ 32V 直流电
工作温度: - 40 ~ +85C ( - 40 ~ +185 ° F )
开关量输入: 4 - 接地或电源正极
开关量输出: 2 - 沉降输出 ( 500mA )
热电偶输入 1 : 1 - K 型热电偶
模拟信号输入 2 :
1 - 电源供电电压(专用)
7 - 0 ~ 5V 直流电 , 4 ~ 20mA ,或摩菲阻抗传感器 3
速度信号输入: 2 ~ 120V 交流电 RMS
30 ~ 10 , 000Hz |
通讯端口: CAN J1939
LED 指示灯:
PWR - 接通电源
COP - 计算机工作正常
CAN - CAN 总线通信正常
产品重量: 10 盎司( 283 . 5 克)
装运重量: 12 盎司( 340 . 2 克)
装运尺寸 : 102 x 152 x 51 毫米
( 4 x 6 x 2 英寸) |
1 使用热电偶输入时,可用的模拟信号输入由 8 个减为 6 个。
2 模拟信号输入端也可输入开关量(接地),最多达 10 个开关量输入。
3 如需支持其它阻抗传感器,请与摩菲公司联系进行定制。
安装尺寸图 尺寸单位:英寸 [ 毫米 ]
插针 |
描述 |
插针 |
描述 |
1 |
开关量输入 2 |
1 |
开关量输出 1 |
2 |
开关量输入 3 |
2 |
RS485 ( - ) |
3 |
模拟信号输入 6 |
3 |
RS485 ( + ) |
4 |
模拟信号输入 4 |
4 |
CAN 高 |
5 |
模拟信号输入 2 |
5 |
CAN 低 |
6 |
K 型热电偶输入 ( - ) |
6 |
电源 ( + ) |
7 |
K 型热电偶输入 ( + ) |
7 |
电源 ( - ) |
8 |
模拟信号输入 1 |
8 |
程序下载 |
9 |
模拟信号输入 3 |
9 |
暂不使用 |
10 |
模拟信号输入 5 |
10 |
开关量输入 4 |
11 |
模拟信号输入 7 |
11 |
开关量输出 2 |
12 |
开关量输入 1
|
12 |
转速传感器输入 |
如何订购
产品型号: XM500
Electrical
- Power Input: 8 to 28VDC
- Communication Ports: CAN J1939
- Operating Temperature: -40°F to 185°F (-40°C to 85°C)
- Digital Inputs: 4 - Ground or battery positive activation
- Digital Outputs*: 2 Sinking (500 mA)
- Product Weight: 10 ounces
- Shipping Weight: 12 ounces
- Shipping Dimensions: 4” x 6” x 2”
*(Outputs are NOT reverse polarity protected. Damage will occur if B+ is connected to the outputs. Damage incurred from improper installation is not covered under the Murphy limited warranty policy.)
- Thermocouple Input 1 : Type K and Type J
- Analog Inputs 2 :
- 1 - Battery Supply Voltage (dedicated)
- 7 - Configurable as 0-5VDC, 4-20mA, resistive senders 3 or used as an additional digital input
- Speed Sensing Input: Magnetic pickup (2 to 120VAC RMS from 30 to 10,000 Hz)
1 When the thermocouple input is used, only 5 resistive, 4-20 mA, or 0-5 VDC can be used instead of 7.
2 Analog inputs can be exchanged for digital inputs (battery ground activation only) for a total of 11 digital inputs.
3 Other resistive senders can be supported. Contact Murphy's Industrial Panel Division for programming charges.
- How to order
Part Number Model/Description Notes
Part Number |
Model/Description |
Notes |
78700420 |
XM500 Murphy Standard* |
Module |
78700534 |
XM500 Configuration Tool |
Tool |
30000669 |
6' harness with terminating resistor |
Wire Harness |
30000685 |
6' harness without terminating resistor |
Wire Harness |
30000670 |
12' harness with terminating resistor |
Wire Harness |
30000686 |
12' harness without terminating resistor |
Wire Harness |
* To determine other configurations, review XM500 Config & Wiring documents.
- Downloads产品技术资料下载
Sales Bulletin (0710175)
|