MURPHY PowerView PVM Gauges J1939 CAN/MurphyLink
Murphy PowerView PVM仪表
Murphy PVM的系列计的智能计用于显示容易读取信息转发PowerView。 PVM的计沟通PowerView通过单个485 双绞线Modbus RTU通讯串行链路。该计可以菊花链使用快速连接线束。 PVM的计主要特点是其设计和功能之间的平衡。这些现代计提供了边框样式和颜色选择于本文件第3所示。计的PVM的还包括,如顺利的步进为270扫描指针,一个有两个放大器微型通用伴侣氮密封的环境下电机运行特性乐连接塑造成的外壳,和绿色LED背光照明。
产品名称:MURPHY PowerView PVM仪表.PDF
Murphy PowerView PVM仪表特点:
- 现代电子设备的使用发动机和汽车工程师协会J1939控制器局域网
- 显示汽车工程师协会J1939的PowerView系统播放的参数。
- 尖端,步进电机技术和强大的功能相结合,高精度驱动微处理器
- 简单的安装和布线设计
PowerView PVM Gages
For modern electronic engines and equipment using SAE J1939 Controller Area Network
Display SAE J1939 parameters broadcast by the PowerView system.
Cutting-edge, stepper motor technology and robust functionality combined
Microprocessor driven for high accuracy
Simple installation and wiring design
Description
The PowerView PVM Series gages are intelligent gages designed to display easy-to-read information transmitted by the PowerView. The PVM gages communicate with the PowerView via a single RS485 twisted pair MODBUS? RTU serial link. The gages can be daisy-chained using quick-connect harnesses.
The major feature of the PVM gages is their balance between design and functionality. These modern gages offer a selection of bezel styles and colors shown on page 3 of this document.
The PVM gages also include features such as a smooth stepper motor operation for the 270° sweep pointer, an environmentally sealed case with two Amp Mini Universal Mate-N-Lok connectors molded into the casing, and green LED back lighting. They are available for standard 2-1;16 in. (52 mm) and 3-3/8 in. (86 mm) diameter hole sizes. In addition their plastic cases incorporate a “D” shape allowing panel cutouts that eliminate gage rotation during installation.
PVM20 Series Models
- PVM20-A = Engine Oil Pressure
- PVM20-B = Coolant Temperature
- PVM20-C = Voltmeter
- PVM20-D = Percent Load at current RPM
- PVM20-E = Transmission Oil Pressure
- PVM20-F = Transmission Oil Temperature
- PVM20-G = Engine Oil Temperature
- PVM20-H = Hydraulic Oil Temperature
- PVM20-J = Percent Fuel Level
- PVM20-K = Boost Pressure
- PVM20-L = Exhaust Gas Temperature
- PVM20-M = Intake Manifold Temperature
- PVM20-N = Auxiliary Temperature
- PVM20-P = Auxiliary Pressure
- PVM20-T = Tachometer
PVM35 Series Models
- PVM35-T = Tachometer
- PVM35-S = Speedometer
The PowerView PVM Series Gages are intelligent gages designed to display easy-to-read information transmitted by PowerView. The PVM gages communicate with PowerView via a single RS485 twisted pair MODBUS RTU serial link. The gages can be daisy-chained using quick-connect harnesses.
The major feature of the PVM gage is its balance between design and functionality. These modern gages offer a selection of lens and bezel styles and colors.
The PVM gages also include features such as a smooth stepper motor operation for the 270° sweep pointer, an environmentally sealed case with two Amp Mini Universal Mate-N-Lok connectors molded into the casing, and green LED backlighting. They are available for standard 2-1/6” (52mm) and 3-3/8” (86mm) diameter hole sizes. Their plastic cases incorporate a D shape allowing panel cutouts that eliminate gage rotation during installation.
PVM20 Series Models
- PVM20-A = Engine Oil Pressure
- PVM20-B = Coolant Temperature
- PVM20-C = Voltmeter
- PVM20-D = Percent Load at current RPM
- PVM20-E = Transmission Oil Pressure
- PVM20-F = Transmission Oil Temperature
- PVM20-G = Engine Oil Temperature
- PVM20-H = Hydraulic Oil Temperature
- PVM20-J = Percent Fuel Level
- PVM20-K = Boost Pressure
- PVM20-L = Exhaust Gas Temperature
- PVM20-M = Intake Manifold Temperature
- PVM20-N = Auxiliary Temperature
- PVM20-P = Auxiliary Pressure
- PVM20-T = Tachometer
PVM35 Series Models
- PVM35-T = Tachometer
- PVM35-S = Speedometer
Specifications
PV101 Compatibility
- Maximum supported : 5 PVM gages
- Maximum distance to last gage : 8.5 meters
- Power Supply Input Voltage : 5V (4.5-5, 5.5 VDC minimum & maximum voltage)
- Power Supply Operating Current (@ 5 VDC): PVM20, PVM35: 18 mA minimum; 80 mA maximum
- Backlight Maximum Current : 60 mA
- Input : RS485 MODBUS RTU data
- Output : Analog readout
Environmental
- Operating Temperature : -40° to 185°F (-40° to 85°C)
- Storage Temperature : -67° to 185°F (-55° to 85°C)
- Environmental Sealed Enclosure :
- Sealing : IP68, ±5PSI (±34.4 kPa)
- Case and Clamp Material : Polyester (PBT)
- Lens Material : Polycarbonate
- Bezel Material : Polyester (PBT)
- Dial : White numerals over black background
- Return-to-Zero Needle Movement : Not available for PVM20 models
- Indicating Pointer : Stepper motor operation with 270° sweep
- Gage Accuracy : Better than ±1.0% of scale
- Maximum Panel Thickness : 3/8 in. (9.6 mm)
- Connectors :
- Amp Mini Universal Mate-N-Lok
- Amp Plug P/N: 172338-1
- Amp Socket P/N: 171639-1
- Shipping Weight : 1 lb. (450 g)
- Shipping Dimensions : 6 x 6 x 6 in. (153 x 153 x 153 mm)
For more information about this product, you can download the related literature here:
|