MURPHY HD9063, OS77D, SS300 Electronic Speed Switches
电子速度开关
根据特定的速度开关模型和应用,这些紧凑型装置从不同来源接收输入信号。它们有单或双开关点型号,开关点可现场调节。型号有独立的外壳和PC板设计,可包含在您的控制柜中。所有的墨菲速度开关都设计用于恶劣的环境中,并且具有高的电噪声抗扰性。墨菲电子速度开关有多种配置,以涵盖广泛的应用。根据特定的速度开关模型和应用,这些紧凑型装置从不同来源接收输入信号。
These compact devices receive their input signal from various sources depending upon the particular speed switch model and application. They are available in single or dual switch point models, and the switch point(s) are field adjustable. Models are available in self-contained enclosures and as PC-board design for inclusion in your control cabinet. All Murphy speed switches are designed to operate in harsh environments and have high electrical noise immunity.Murphy Electronic Speed Switches are available in various configurations to cover a wide variety of applications. These compact devices receive their input signal from various sources depending upon the particular speed switch model and application.
Electronic Speed Switches HD9063, OS77D and SS300 Series PDF Catalog
They are available in single or dual switch point models and the switch point(s) are field adjustable. Models are available in self-contained enclosures and as PC-board design for inclusion in your control cabinet. All Murphy speed switches are designed to operate in harsh environments and have high electrical noise immunity.
Features:
- Models for overspeed, crank termination, or crank termination and overspeed solid state construction
- Compact design
- Field adjustable set points
- High noise immunity
Series Models Available
SS300 Series: Single set point speed switch with SPDT relay dry contact output.
SS300 (std. model)
SS300-LF (low frequency)
SS300-AD (adjustable differential)
SS300-AD-LF (low frq. & Adjst. diff.)
OS77D Series: Single set point speed sensing module, with a transistor output.
HD9063 Series: Dual set point speed switch in a pc board configuration and relay outputs.
. HD9063 Model
Crank Disconnect: 250-6,000 Hz
Overspeed: 1,100-10,000 Hz
. HD9063-USOS Model
Underspeed: 200-5,800 Hz
Overspeed: 1,100-10,000 Hz
Reset Differential, Magnetic Pickup Signal Models
. HD9063 Model
Crank Disconnect: Dropout 160 Hz ± 5%
Overspeed: 200 Hz Differential
. HD9063-USOS Model
Underspeed: +5% of Set point Differential
Overspeed: 155 Hz ± 10% Differential
Output: Relay Contact, SPDT, Resistive Load: (2) 5 A, 30 VDC
Adjustment: (2) 270°–turn potentiometer
Temperature Range: 14 to 158°F (-10 to 70°C)
Model Length Length Size
MP3298* 3 in. (76 mm) 3 in. (76 mm) 5/8-18 UNF
MP7906. 3 in. (76 mm) 3 in. (76 mm) 3/4-16 UNF
MP7905.. 4-1/2 in. (114 mm) 4-1/2 in. (114 mm) 3/4-16 UNF
*Replaces 20-01-0080 and MP100. Lead wire hookup (12 in. [305 mm]).
.Replaces 20-01-0081. Lead wire hookup (12 in. [305 mm]).
..Replaces 20-01-0082. Lead wire hookup (12 in. [305 mm]).
Electronic Speed Switches HD9063, OS77D and SS300 Series PDF Catalog
HD9063, OS77D AND SS300
Murphy Electronic Speed Switches are available in various configurations to cover a wide variety of applications.
HD9063 Specifications
Power Supply: Voltage: 8-30 VDC. Maximum Current: 150 mA.
Frequency Signal: (Voltage, Magnetic Pickup Signal Models):
Minimum: 0.35 Vrms.
Maximum: 60 Vrms.
Maximum Current, Magnetic Pickup Signal Models: 4.8 μA.
Adjustment Range, Magnetic Pickup Signal Models:
Crank Disconnect: 250-6,000 Hz.
Overspeed: 1,100-10,000 Hz.
Reset Differential, Magnetic Pickup Signal Models:
Crank Disconnect: Dropout 160 Hz ± 5%.
Overspeed: 200 Hz Differential.
Output: Relay Contact, SPDT, Resistive Load: (2) 5 A 30 VDC.
Adjustment: (2) 270°–turn potentiometer.
Temperature Range: 14 to 158°F (-10 to 70°C).
Shipping Weight: 2 lbs. (0.90 Kg).
Shipping Dimensions: 10 x 9 x 6 in. (254 x 229 x 152 mm).
Series Models Available
SS300 Series: Single set point speed switch with SPDT relay dry contact output.
OS77D Series: Single set point speed sensing module with a transistor output.
HD9063 Series: Dual set point speed switch in a PC board configuration and relay outputs.
Murphy speed switches applications include operating alarms and equipment shutdown. They are ideal for disconnecting starter cranking on auto start systems or overspeed switching:
Applications
Generators
Compressors
Industrial Engines
Pumps
Vehicles
Farm Equipment
Selecting a Speed Switch
In selecting the best Speed Switch for your application, the following factors should be considered:
Number of Switch Points How many switch points are needed to perform the speed switching function you require?
Available Signal Sources The signal source must provide a minimum frequency and a minimum, but less than maximum, voltage as required by the selected speed switch.
What Is the Frequency Output of the Signal Source? The following signal sources can be used with most Murphy Electronic Speed Switches.
Note: they may additionally provide the signal and/or power source for some Murphy Tachometer/ Tachswich? instruments.
Magnetic Sensor: The sensor is usually mounted through the flywheel housing so that the sensor tip is in close proximity to the ring gear teeth. Output voltage is dependent upon the amount of the gap between the sensor tip and the gear tooth.
Alternator Output: Most industrial engine alternators have an auxiliary or tachometer tap. This tap can provide the signal source for speed switches and tachometers.
Ignition Output: This battery ignition signal is commonly used on gasoline and natural gas fueled type engines. The tap is usually located either on the distributor or on the ignition coil. The ignition can be breaker point type or all electronic.
Signal Generators: Add-on signal generators produce a voltage and frequency output. Match this output to the requirements of the speed switch selected.
SS300 Series
The SS300 Series are single set point speed switches with SPDT relay dry contact output. The trip point is set by a potentiometer. An LED indicates when the signal source is present. A second LED turns on when the trip point is reached. See Table 1 for available models and requirements. An optional time delay is on board to delay operation of the relay for 2-6 seconds after the set point has been reached. The SS300 Series speed switch is intended for installation within a weatherproof enclosure to protect it from rain, dust, etc. Application Overspeed shutdown. Shuts down the engine if RPM exceeds the preset limit. Speed sensitive pull-in/drop-out. Engage or disengage PTOs, four-wheel drives, other switch points, etc. according to the engine speed being monitored. Engine and transmission alarms/shutdowns. Oil pressure in some engines and transmissions varies widely between running and idle speeds. The SS300 Series can select between two pressure switch set points according to speed of the engine or transmission and thus give maximum protection to the equipment while at operating RPM and eliminate nuisance alarms when at idle. Adjustable differential model. The AD can be adjusted to change the speed range over which the pull-in and drop-out differential of the relay will operate. A typical application is to ensure that engine speed is above a minimum RPM before applying a load but allows a drop in speed of several hundred RPM without disconnecting the load.
HD9063 Series
The HD9063 Series is a unitized two set point speed switch with SPDT relay outputs. HD9063 is a PC-board configuration with standoffs for mounting in a control panel or cabinet. The HD9063 provides crank disconnect and overspeed functions. Trip points can be field adjusted on all models. LEDs next to the set point potentiometers indicate that the trip point has been reached and the relay(s) have operated. An overspeed test circuit is built-in. It will actuate the output relay at a point 10 percent below the actual overspeed set point. Application Crank disconnect/overspeed are functions where the HD9063 is used to disconnect the starter on automatic start engine applications and to shut down the engine if an overspeed situation occurs. Re-engagement of the starter is inhibited until RPM returns virtually to zero. Typical applications include: standby generator sets, pumps and compressors
OS77D Series
The OS77D Series single set point speed switch is a compact all-electronic speed sensing module. It can be panel mounted via its trip set point potentiometer. It is field adjustable and gives a transistor output when tripped. Relay models available. Models are available with Normally Open or Normally Closed circuit and with or without re-crank feature, which inhibits starter re-engagement until the engine speed is near zero RPM. Application Overspeed shutdown. Activates engine shut-down circuit on engine overspeed. Operate PTOs or drive circuits. Engage or disengage engine PTO, four-wheel drives or other control circuits according to RPM monitored. Disconnect engine cranking when engine starts.
Series Models Available
SS300 Series : Single set point speed switch with SPDT relay dry contact output.
OS77D Series : Single set point speed sensing module with a transistor output.
HD9063 Series : Dual set point speed switch in a PC board configuration and relay outputs.
Murphy speed switches applications include operating alarms and equipment shutdown. They are ideal for disconnecting starter cranking on auto start systems or overspeed switching:
Applications
- Generators
- Compressors
- Industrial Engines
- Pumps
- Vehicles
- Farm Equipment
For more information about this product, you can download the related literature here:
|